The insertion loss of DUT3 on 1296 measured with SDR-IP mixers and HP generators.
(March 10 2013)



Observed signal levels:

 none         DUT3
114.8467    114.8264
114.8445    114.8247
114.8441    114.8261 
114.8457

      averages 
114.8452    114.8257
standard deviations on individual measurements
  0.0012    0.0009
Standard deviations on averages
  0.0006    0.0005
IL = 114.8452 -  114.8257 = 0.0195 dB
Standard deviation 0.0008 dB
Error limits (3 sigma) +/- 0.0024 dB

Errors are estimated from too few data points so
the error estimation for this particular measurement is 
uncertain.
There are many measurements in this series so the statistics