[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [linrad] IC706MKIIG



Leif  I use the 706 on cw but it  has a bad reputation for cw clicks 
when set for full break-in. Try it without full break-in.  It also 
likes to have a good solid 13 Volts and if using a battery supply 
this is often hard to achieve.


>Hi All,
>
>I am doing some measurements on a IC706MKIIG, but I do not have
>the operators manual. The unit is fine on 144 MHz, but on 14 MHz
>the ALC turns down the power after it initially has been a bit above
>the steady state level soon after key-down.
>
>The AGC action is fast and causes terrible keying clicks. Is there
>anyone in this group who knows if I am operating the unit improperly?
>In other words: Is there a drive level I should set some way according
>to the operators manual or is the unit defective because some internal
>level is incorrectly set? I find it hard to believe that these keying
>clicks are normal for the IC706MKIIG - on 144 MHz the keying is superb.
>
>
>73
>
>Leif / SM5BSZ

-- 
73
Ron
W6WO
LINRADDARNIL
<